(M5576 DIP8-120W)测试数据 | |||||||||
1 | 待机功耗 (mW) | 220 | 234 | 217 | |||||
2 | 输入电流 (mA) | 2138 | 2171 | 2150 | |||||
3 | 输出电压 (V) | 23.554 | 23.554 | 23.554 | |||||
4 | 输出电流 (A) | 6.19 | 6.32 | 6.09 | |||||
5 | 过流保护 | 85V ( A) | 6.4 | 6.36 | 6.3 | ||||
110V ( A) | 7.1 | 7.13 | 7.1 | ||||||
220V ( A) | 7.9 | 7.88 | 7.9 | ||||||
264V ( A) | 7.9 | 7.91 | 7.9 | ||||||
6 | 效率( %) | 115V | 100%负载 | 88.67 | 88.82 | 88.68 | |||
75%负载 | 89.45 | 89.45 | 89.52 | ||||||
50%负载 | 90.23 | 90.31 | 90.2 | ||||||
25%负载 | 90.24 | 89.93 | 89.76 | ||||||
230V | 25%负载 | 88.77 | 88.33 | 88.1 | |||||
50%负载 | 89.82 | 89.6 | 89.68 | ||||||
75%负载 | 90.26 | 90.18 | 90.13 | ||||||
100%负载 | 90.23 | 89.49 | 89.9 | ||||||
平均效率 | 89.70875 | 89.51375 | 89.49625 | 0 | 0 | 0 | |||
7 | OVP过压 V | 36.4 | 34 | 37.2 | |||||
8 | 过流保护 重启时间 S | 5.36 | 5.76 | 5.4 | |||||
9 | 空载启动电压 V | 38 | 34 | 36 | |||||
10 | 重载启动电压 V | 81 | 83 | 86 | |||||
11 | 启动延时时间 S | 11.3 | 11.4 | 12.5 | |||||
12 | 关断维持时间 mS | 10 | 11.6 | 8.4 | |||||
13 | DC上升时间 mS | 51.2 | 56 | 63 | |||||
14 | DC下降时间 mS | 21.2 | 20.8 | 21.4 | |||||
15 | 电压调整率 __% | <0.1% | <0.1% | <0.1% | |||||
16 | 电流调整率 __% | <0.1% | <0.1% | <0.1% | |||||
17 | 纹波与噪声 mV | ||||||||
18 | 短路功率(瞬间/平均)W | 17/0.21 | 16/0.14 | 15/0.25 |